N2 - One of the main challenges in the application of coupled or integrated hydrologic models is specifying a catchment's initial conditions in terms of soil moisture and depth-to-water table (DTWT) distributions. One approach to reducing uncertainty in model initialization is to run the model recursively using either a single year or multiple years of forcing data until the system equilibrates with respect to state and diagnostic variables. However, such "spin-up" approaches often require many years of simulations, making them computationally intensive. In this study, a new hybrid approach was developed to reduce the computational burden of the spin-up procedure by using a combination of model simulations and an empirical DTWT function. The methodology is examined across two distinct catchments located in a temperate region of Denmark and a semi-arid region of Australia. Our results illustrate that the hybrid approach reduced the spin-up period required for an integrated groundwater-surface water-land surface model (ParFlow.CLM) by up to 50%. To generalize results to different climate and catchment conditions, we outline a methodology that is applicable to other coupled or integrated modeling frameworks when initialization from an equilibrium state is required.
AB - One of the main challenges in the application of coupled or integrated hydrologic models is specifying a catchment's initial conditions in terms of soil moisture and depth-to-water table (DTWT) distributions. One approach to reducing uncertainty in model initialization is to run the model recursively using either a single year or multiple years of forcing data until the system equilibrates with respect to state and diagnostic variables. However, such "spin-up" approaches often require many years of simulations, making them computationally intensive. In this study, a new hybrid approach was developed to reduce the computational burden of the spin-up procedure by using a combination of model simulations and an empirical DTWT function. The methodology is examined across two distinct catchments located in a temperate region of Denmark and a semi-arid region of Australia. Our results illustrate that the hybrid approach reduced the spin-up period required for an integrated groundwater-surface water-land surface model (ParFlow.CLM) by up to 50%. To generalize results to different climate and catchment conditions, we outline a methodology that is applicable to other coupled or integrated modeling frameworks when initialization from an equilibrium state is required.
UR - http://www.scopus.com/inward/record.url?scp=84918528663&partnerID=8YFLogxK
U2 - 10.5194/hess-18-5169-2014
DO - 10.5194/hess-18-5169-2014
M3 - Article
SN - 1027-5606
VL - 18
SP - 5169
EP - 5179
JO - Hydrology and Earth System Sciences
JF - Hydrology and Earth System Sciences
IS - 12
ER -