Abstract
Passive flux samplers were used to determine the ammonia exchange on an inland heath in Denmark over the last 2 years. The samplers measured the horizontal ammonia flux directly. Data were sampled continuously for periods of 1-4 weeks. The micro-meteorological gradient method was used with passive flux samplers and cup anemometers at different heights above the vegetation in order to calculate the vertical fluxes of ammonia. First a fixed sampler system was used with tubes mounted in four orthogonal horizontal directions. This system has been successfully applied to measure the emission from fertilized crops. Adapting this type of sampler to measure the deposition to heathlands did not prove to be straightforward. The precision of the calculated ammonia concentrations was too poor to give an acceptable accuracy for the concentration gradient. The problems were (a) driving rain which entered the tubes,(b) too few measuring points in each concentration profile, and (c) too long sampling periods to allow for the low-concentration levels above the heath area and the detection limits. Therefore, a passive flux sampler mounted on a wind vane and fitted with a rain shelter was developed. Results from the first 5 weekly periods are very promising, yielding accurate concentration gradients. The advantages of the passive flux samplers on the wind vane are (a) the minimum measuring period can be approximately halved compared to the fixed samplers, (b) some of the directional correction terms used with the fixed passive flux samplers are dispensed with, and (c) the field and laboratory work is minimized.
| Original language | English |
|---|---|
| Pages (from-to) | 461-464 |
| Number of pages | 4 |
| Journal | Atmospheric Environment |
| Volume | 32 |
| Issue number | 3 |
| DOIs | |
| Publication status | Published - 1 Feb 1998 |
| Externally published | Yes |
| Event | Proceedings of the 1995 International Conference on Atmospheric Ammonia: Emissions, Deposition and Environmental Impacts - Culham, UK Duration: 2 Oct 1995 → 4 Oct 1995 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 6 Clean Water and Sanitation
Keywords
- Ammonia deposition
- Long-term measurements of atmospheric ammonia
- Passive flux samplers
- The micro-meteorological gradient method
- Wind-vane flux sampler
Programme Area
- Programme Area 2: Water Resources
Fingerprint
Dive into the research topics of 'Atmospheric ammonia exchange on a heathland in Denmark'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver